Ethylene Oxide Sterilizer EOS-A10

The EOS-A10 Ethylene Oxide Sterilizer is a vertical, constant temperature heating box-type sterilizer cabinet with a manual door opening, providing a capacity of 80 L. It operates at a sterilization temperature of 50 ℃ and a work pressure of -60 kPa. The sterilization room is constructed of 304 anti-corrosion type stainless steel, while the outer box material is 1.8 mm thick carbon steel baked with plastic powder using the electric heating method. The sterilizer features automatic ventilation at 30-minute intervals. It is equipped with a built-in temperature, humidity, and pressure sensor, along with an automatic control system that ensures stability, efficiency, and quality. The digital LCD screen displays temperature, humidity, pressure, sterilization time, residual treatment time, and the number of cycles. Additionally, a built-in printer records and verifies the entire sterilization process. The sterilizer incorporates an explosion-proof electric heating device with over-voltage and over-temperature protection, as well as a residual air automatic processing system for reliable operations.

Specifications

Type Vertical; constant temperature heating box type
Door opening Manual
Capacity 80 L
Sterilization temperature 50℃ ± 3℃
Work pressure -60 kPa
Maximum pressure -140 kPa
Humidity (sterilization) 45% to 75%
Sterilizing gas Ethylene oxide; 1g/L
Sterilization time 0 to 99 hrs; adjustable
Vacuum speed -60 kPa in 15 mins
Ventilation Automatic
Ventilation cycle 3 times; 30 mins interval once
Control system Automatic; one-button
Display Digital LCD display
Printer Yes
Humidity sensor Yes; cavity humidity: >45% RH
Pressure sensor Yes
Temperature sensor Yes; cavity temperature: 50℃ ± 3℃ (within precise range)
Vacuum system Oil free vacuum pump
Heating system Electric; explosion-proof electric heating device
Alarm system High/low temperature
Protection features over-voltage, over-temperature protection, residual air automatic processing system
Sterilization room material 304 anti-corrosion type stainless steel
Outer box material Carbon steel (thickness 1.8mm) baked plastic powder
Wear parts Seal
Caster Yes
Power 1.5 kW
Chamber dimensions (W×D×H) 320×600×450 mm
Dimensions (W×D×H) 620×780×1100 mm
Weight 176 kg

Features

  • Vertical, constant temperature heating box type ethylene oxide sterilizer cabinet with manual door opening.
  • 304 stainless steel for the sterilization room and carbon steel baked with plastic powder for the outer box, using the electric heating method.
  • Automatic ventilation with 3 cycles, providing ventilation at 30-minute intervals.
  • Digital LCD display with an automatic control system and built-in printer for monitoring and recording.
  • Built-in sensors for humidity, pressure, and temperature, ensuring precise and effective control.
  • Equipped with an oil-free vacuum pump and an explosion-proof electric heating device for convenience.
  • High and low-temperature alarm system for enhanced safety measures.
  • Incorporated with casters for easy movements and enhanced mobility.
  • Sealed wear parts to maintain integrity during operation.
  • Simple and convenient operation with a long service life.

Applications

The Ethylene Oxide Sterilizer is employed for the sterilization of a diverse range of items such as catheters, resuscitation bags, anesthesia masks, fiber-optic instruments, glassware, solution mediums, assembled complex devices, custom procedure packs, equipment with integrated electronics, multi-lumen tubing products, stents, wound care dressings, and more. It finds widespread application in pharmaceutical industries, metal and glass industries, hospitals, laboratories, research institutes, and similar settings. Particularly suitable for prosthetic implants, including joint, hip, and knee replacements, this autoclave is designed to meet the stringent sterilization requirements in various medical and industrial contexts.